Guarded Button

Guarded Buttons are special types that require positive action for three seconds before triggering an output.

Action Map

The action map below details the point at which commands are sent

Touch ReadyTouch BeginTouch Hold (after 3 secs)Touch ReleaseTouch End
XXOn ModeXX

Control Methods

TypeOn ModeOff Mode
MIDIMIDI Channel, Note, VelocityN/A
OSCOSC Message, PatchN/A
HTTPHTTP Address, PatchN/A
TCPTCP String, PatchN/A
UDPUDP String, PatchN/A

API Methods

Use external applications to operate this control with the API via OSC.

Send the string /ctrl/control/[uid]/[command] with the control's UID and selected command

The default port for Ctrl for iPads OSC API is 53000. This can be modified by navigating to the settings menu and modifying the global OSC input port

OSC Commands

Command
/enabled [Int]Enable or disable the control (0 - Disabled, 1 - Enabled)
/label [String]Change the label of the control for the session
/theme [Int]Change the theme of the control (Int 1 to 14)
/theme [Int] [String]Change the theme of the control using custom palette name (Int 1 to 14)